1000 HOUR IN SALT FOG ATMOSPHERE

ZAVRpos.jpg (12158 bytes)ZAVRiskre.jpg (9708 bytes)

 

RIGHT: partial discharge on cable termination EMOT 3110 in salt fog atmosphere.

LEFT: cable termination EMOT 3110 outside salt fog atmosphere and dry. White: salt sediment on surface.

 

 

Testing in accordance with : IEC 61442/1997 ( dot 13 ) at 25 kV.

 

 

2001.05. 16.-17.

VISIT AND TRAINING IN "MOELLER"(F&G), Schrems, Austria

ELPLAST workers paid a working visit to the "MOELLER Gebäudeautomation KG" whose optical program ELPLAST represents in Croatia, Slovenia, BiH, Montenegro, Macedonia and Albania. Two days of visit were utilized for wide program of training for application of optical fibers jointing accessories and factory sight-seeing. In spite of exhausting program, hosts did everything to make our visit well organized and easily fulfilled.

MOELLER1.jpg (23083 bytes)

 

 

 

 

 

 

 

 

Moeller2.jpg (19827 bytes)

 

 

 

 

 

 

 

 

 

Moeller3.jpg (19549 bytes)

 

 

 

 

 

 

 

 

 

 

 

2001.05.25.

PRESENTATION IN HEP-DP "ELEKTRA VINKOVCI "

With kindness of our host, ELPLAST visited HEP-DP " ELEKTRA VINKOVCI ", and successfully presented it's production program of heatshrinkable technology for cable joints and termination for low and medium voltage up to 36 kV.

Beside the theoretical part, the practical part of the presentation was also done, together with staff of " ELEKTRA VINKOVCI ".

 

VK1.jpg (8981 bytes)VK2.jpg (9759 bytes)

 

 

 

 

 

 

 

VK3.jpg (9863 bytes)VK4.jpg (8604 bytes)

 

 

 

 

 

 

 

VK5.jpg (9076 bytes)

 

 

2001.09. 03.-07.

EDUCATION in "ELPLAST"

ELPLAST company educated three workers from Romanian companies ICMRS and SIDERURGICA for installation of cable joints and terminations for low and medium voltage. During the five day program frequenters pass education successfully in theoretical and practical part, on cable joints EMPJ 3X 3320 and cable terminations EMIT 3X 3320.After the receiving certificates for education, guests were introduced with the sights of  the city of Zagreb and its neighborhood. We are very satisfied with accomplishments and association with gentlemen's and we hope that we will continue with good collaboration as during this five days.

RO1.jpg (13861 bytes)RO2.jpg (14043 bytes)

RO3.jpg (9768 bytes)

RO4.jpg (16737 bytes)RO5.jpg (14052 bytes)

RO6.jpg (14133 bytes)RO7.jpg (16085 bytes)

 

 

2002.02.08

PRESENTATION IN HEP DP ELEKTRA POZEGA

With kindness of our representative, company ALLES d.o.o., we have organized a presentation in Pozega of ELPLAST's production program (joints and terminations for low and medium voltage) in DP Elektra Pozega. There were more than ten HEP representatives attending detailed presentation.

In a discussion, during the presentation, interest was shown for specific problems in connecting cables when fixing damages on the field, especially at medium voltage cables isolated with impregnated paper, type NEHKBA. Experts from Elplast immediately gave concrete answers and solutions on asked questions, with the help of video-projection.

We agreed upon presentation of practical making of the joints and terminations in Educational center in Velika sometime in March.

PZ1.jpg (10334 bytes)PZ2.jpg (11090 bytes)

 

 

 

 

 

 

 

 

2002.05.10.

NEW CONSTRUCTION OF JOINT for 12/20 kV cable (XHE-49A)
EMPJ-1T

In ELPLAST we have developed construction of joint for one core 12/20 kV XHE cables type EMPJ-1T. By contrast to the old construction, here we use only two heat shrinkable tubing's: two layer insulation - semi-conductive and exterior-sealant. Stress control is achieved by combination of special panels, (clothes) which we wrap around the cable. This way we achieved simpler construction, and installation is easier and fast.

New joint was tested with voltage of 4,5 Uo (54kV) for 5 minutes with no break down occured. When we tested partial discharge with voltage of 21 kV, maximum value was 4,5 pC (medium 3,2 pC). According to CENELEC standard, maximum is 10 pC.

EMPJ-1T2.jpg (8179 bytes)EMPJ-1T3.jpg (6140 bytes)

 

 

 

 

 

 

 

EMPJ-1T4.jpg (7132 bytes)EMPJ-1T5.jpg (6159 bytes)

 

 

 

 

 

 

 

 

EMPJ-1T6.jpg (10677 bytes)EMPJ-1T7.jpg (12417 bytes)

 

 

 

 

 

 

 

 

2002.05.28.

EDUCATIONAL AND PRACTICAL TRAINING IN "ELPLAST"

HEP employees from DP "Elektra Bjelovar" and department Krizevci have been attending course and training of connecting transition joint EMPJ 1X-LS, which we use for connecting paper insulated three core 10kV cable with Pb armature (IPO 13) and plastic insulated armored screened one core 20kV cables (XHE 49-A). Together with Elplast's workers there were assemblers and technical staff from HEP also involved when mounting the joint.
Besides the practical training we introduced HEP employees with complete production program of company "ELPLAST".

 

DPBJ KZ1.jpg (15108 bytes)DPBJ KZ2.jpg (17433 bytes)

 

 

 

 

 

 

 

DPBJ KZ3.jpg (15093 bytes)DPBJ KZ4.jpg (17649 bytes)

 

 

 

 

 

 

 

DPBJ KZ5.jpg (18126 bytes)

 

 

2002.06.12.

PRESENTATION IN "ECM"
(MACEDONIAN POWER COMPANY)

ELPLAST and "EL-BAJT" from Skopje (as Elplast's representative) organized presentation in Macedonian Power Company ("ELEKTROSTOPANSTVO NA MAKEDONIJA"). On well-attended presentation, we presented Elplast's production program. With the help of multimedia we have shown low and medium voltage joints and terminations and installation accessories for power cables. Separately, we presented set for connecting optical cables, LV and MV metal oxide surge arresters. Additional questions and answers, with their specific problems, from their own experience continued great interest of people who attended presentation. Interest and desire for further cooperation was shown, in sense of practical training-mounting joints and terminations, for their assemblers.

SK1a.jpg (10185 bytes)SK2a.jpg (12976 bytes)

SK4.jpg (28297 bytes)

 

 

 

June 19th 2002

TRAINING IN ELPLAST

We had personnel of HEP Varazdin on training in Elplast. In practical part of training a new joint EMPJ-1T has been made for single core

12/20 kV XHE49-A cables and cable termination ELVT-A for four cores plastic insulated cables, voltage level 0,6/1 kV.

16A.jpg (14250 bytes)15A.jpg (18331 bytes)

 

 

 

 

 

 

12A.jpg (14936 bytes)

 

 

 

June 28th 2002

INSTALLATION OF JOINTS AND TERMINATIONS
IN HEP DP "ELEKTRA POZEGA"

 

At the invitation of HEP, DP Pozega, Elplast's workers have made three joints EMPJ 2120 and three terminations for indoor application

EMIT 2120 on cable XHE49-A (12/20 kV, 150mm2). After successful testing, the cable was put into operation.

19A.jpg (25452 bytes)20A.jpg (35775 bytes)

 

 

 

 

 

 

 

 

 

18A.jpg (18197 bytes)14A.jpg (16542 bytes)

 

 

 

 

 

 

13A.jpg (18321 bytes)

 

 

July 08th 2002

INSTALLATION OF JOINTS
in HEP DP "ELEKTRA BJELOVAR"

At the invitation of HEP, DP Elektra Bjelovar, Elplast's workers have made two transition joints EMPJC 1X-LS for transition from single core XHE49-A cables, voltage level 12/20 kV to three core belted IPO12 cable, voltage level 6/10 kV.

DPBJ KZ6.jpg (23618 bytes)

 

February 14th 2003

NEW CABLE JOINT for " CROATIAN RAILWAYS"

For "Croatian Railways" is developed special construction joint for cable type STK & STKA.

Hz5m.jpg (9404 bytes)

Hz4m.jpg (6396 bytes)

 

 

Hz2m.jpg (5816 bytes)

Hz1m.jpg (9978 bytes)

 

 

 

 

 

January 14th 2004

NEW BUS BAR PROTECTION up to 35 kV

In transformer station HEP-a DP ELEKTRA BJELOVAR, department KRIZEVCI

EPBB6.jpg (83955 bytes)

 



 

 

 

 

 

 

EPBB7.jpg (94518 bytes)

 

 

 

 

 

 

 

 

 

 

 

                                                                                                                                                      